Pumps and Turbines
A pump takes power from a shaft and adds energy to a fluid. A turbine takes energy from a fluid and delivers power to a shaft. To calculate shaft power, divide hydraulic power by pump efficiency to find the shaft input, and multiply hydraulic power by turbine efficiency to find the shaft output.
How much power does it take to pump water up and generate on the way down?
Two open reservoirs have a 20 m difference in water level. At 20 L/s the connecting pipe loses 2 m of head in either direction. The pump must supply 22 m to move water uphill. On the return trip, 18 m reaches the turbine. Compare the electrical input and output as you change the flow.
Bar lengths are relative to the electrical input for the selected case.
- Pipe head loss
- 2.00 m
- Pump shaft input
- 5.40 kW
- Turbine shaft output
- 3.18 kW
The pump adds 22.00 m of head. The turbine receives 18.00 m. For equal run times, 53.2% of the electrical energy is recovered.
Follow the calculation at 20 L/s and 20 m of elevation
- Convert the flow. 20 L/s = 0.020 m³/s. With water density ρ = 1,000 kg/m³ and g = 9.81 m/s², each metre of head at this flow represents 196.2 W.
- Pump uphill. Hydraulic power is 196.2 × 22 = 4,316 W. At 80% pump efficiency, the shaft needs 4.316/0.80 ≈ 5.40 kW. A 95% efficient motor draws 5.68 kW.
- Generate downhill. The water supplies 196.2 × 18 = 3,532 W at the turbine. At 90% turbine efficiency, the shaft delivers 3.532 × 0.90 ≈ 3.18 kW. A 95% efficient generator delivers 3.02 kW.
The model holds the reservoir levels and machine efficiencies fixed and uses hL = 2(Q/20)² m, with Q in L/s. Compare equal volumes pumped and returned at the same flow. The recovered percentage describes this example. Actual pumped-storage performance depends on water levels, dispatch, and efficiency across the operating range.
Head, hydraulic power, and efficiency
Head is mechanical energy per unit weight of liquid. At a section, total head includes elevation z, pressure head p/(ρg), and velocity head V²/(2g) for a uniform velocity profile. Pump head is the gain in total head across the machine. Turbine net head is the total head available across it after external waterway losses.
| Quantity | Pump | Hydraulic turbine |
|---|---|---|
| Energy path | Motor → shaft → liquid | Liquid → shaft → generator or driven load |
| Hydraulic power | Added to liquid: ρgQHp | Available from liquid: ρgQHt |
| Shaft power | Input = ρgQHp/ηp | Output = ηtρgQHt |
| Electrical power | Motor input = shaft input / ηmotor | Generator output = shaft output × ηgen |
Use ρ in kg/m³, Q in m³/s, head H in metres, and efficiency η as a decimal. Power comes out in watts. For water near 1,000 kg/m³, hydraulic power in kW ≈ 9.81 × Q (m³/s) × H (m). Check which losses a quoted efficiency includes before multiplying efficiencies together.
Can I convert a pressure-gauge difference straight to head?
When suction and discharge taps are at equal elevation and equal velocity, pump head equals (pd − ps)/(ρg). Otherwise include the differences in velocity head and elevation. Use density at the measured liquid temperature. For a system between tanks, calculate the endpoint head difference and add the pipe and fitting losses.
Which pump or turbine fits the duty?
Pumps: start with required flow and head
- Centrifugal and other rotodynamic pumps
- A rotating impeller transfers energy continuously to the liquid. A volute or diffuser can convert part of the outlet velocity into static pressure. Centrifugal pumps serve water transfer and circulating loops. Multiple stages can provide high head. Axial-flow designs suit large flow at low head. Check viscosity, solids, suction conditions, and the curve at the intended speed.
- Positive-displacement pumps
- A gear, screw, diaphragm, or piston moves a volume per cycle. Speed and displacement largely set the flow. Slip and fluid properties affect delivery. These pumps suit duties such as viscous oil transfer or metering a chemical dose. Discharge resistance can drive pressure up sharply, so the system needs appropriate overpressure protection.
Water turbines: start with net head and available flow
| Runner | How the water does work | Typical duty |
|---|---|---|
| Pelton Impulse | A nozzle converts head into a free jet. Buckets turn the jet, and its momentum change drives the runner. | High head and relatively low flow. |
| Francis Reaction | Water enters a flooded runner with radial and tangential velocity components and exits generally axially. Static pressure changes through the runner. | A broad middle range of heads, extending into higher-head service. Common in conventional hydro and reversible pump-turbines. |
| Kaplan Reaction | Water passes axially through a propeller-type runner with adjustable blade pitch. | Low head and large flow. Blade and guide-vane adjustment helps accommodate variable conditions. |
These ranges overlap. Use the site’s flow-duration data, seasonal net head, and supplier efficiency map to compare expected energy production. A machine with the highest peak efficiency can produce less annual energy if the site spends most of the year far from that point.
How do you find a pump’s operating point?
A fixed-speed centrifugal pump operates where its head–flow curve intersects the system curve. The pump curve describes the head it can deliver. The system curve describes the head the installation requires at each flow. In this water-transfer example, there is 10 m of static lift even at zero flow.
Baseline operating point: 20.00 L/s at 20.00 m of head.
Illustrative curves use Hpump = 30 − 0.025Q² and Hsystem = 10 + KQ², with Q in L/s and head in metres. At baseline, K = 0.025 m/(L/s)². Throttling raises K to 0.075. The intersection moves to 14.14 L/s at 25.00 m. The static lift and pump speed stay the same. The valve changes the loss in the piping system.
On the manufacturer’s curve for the specified impeller and speed, read efficiency, shaft power, and required NPSH at the operating flow. The best efficiency point (BEP) is where pump efficiency peaks. The system intersection can fall on either side of it. Use the supplier’s operating range to check the expected duty. For a real line, start with the pump head calculator.
Why can a pump or turbine cavitate?
When local absolute pressure falls to the liquid’s vapor pressure, vapor cavities can form. They collapse as pressure recovers, causing noise, vibration, and sometimes surface erosion. A positive discharge-gauge reading can coexist with low local pressure at an impeller inlet or on a turbine blade.
For a pump, compare NPSH available with NPSH required at the actual flow. Available net positive suction head is the inlet total absolute head above vapor-pressure head, referred to the pump datum. A lower supply level, higher liquid temperature, or a clogged suction strainer can reduce it. Allow the application-specific margin recommended for the machine. If a curve specifies NPSH₃, it marks a 3% drop in first-stage head due to cavitation. Vapor formation can begin before the pump reaches that point.
For a reaction turbine, runner elevation relative to tailwater, local blade pressures, and draft-tube conditions affect cavitation. Check the supplier’s setting and performance limits across the operating head range.
Where do pumps and turbines work together?
In pumped-storage hydropower, electrical power raises water when energy is available. Later, descending water drives a turbine and generator. A reversible pump-turbine can use a single runner in both modes. The plant can also use separate machines. Over a cycle, the electricity recovered depends on waterway, machine, and electrical losses.
In an industrial water system, a pump may be needed to deliver flow to an elevated process. A turbine can recover energy elsewhere if the process already has excess pressure and a sustained flow. Estimate that recoverable power from the pressure drop the downstream process can spare, and verify the measured flow before applying efficiency.
Common questions about pumps and turbines
Can an ordinary pump run as a turbine?
Some centrifugal pumps can operate in reverse energy-transfer mode. Their turbine-mode head, flow, efficiency, and speed characteristics differ from their pump curves. Use turbine-mode data and check mechanical and generator constraints before evaluating a specific duty.
Does doubling flow double the power?
At unchanged head and efficiency, yes. In a real pipe, friction head generally rises as flow rises. In the reservoir example it scales with Q², so the pump’s hydraulic power for friction alone scales with Q³. The static-lift portion scales with Q.
Do the same head equations work for steam or gas turbines?
Steam and gas turbines also extract shaft work, but their fluid density and thermal state can change substantially. Analyze the stagnation enthalpy drop and mass flow for those machines. The liquid-water calculations on this page assume nearly constant density.
Engineering references
- Hydraulic Institute — Pump curves explains head, efficiency, input power, and suction requirements. Its pump definitions distinguish NPSH required from NPSH₃.
- Hydraulic Institute — Pump system operating point shows how a system curve sets duty.
- U.S. Department of Energy — Types of hydropower turbines compares impulse and reaction machines.
- U.S. Department of Energy — Pumped storage hydropower describes the pumping and generating cycle.