Incompressible Flow
Incompressible flow is motion in which each fluid parcel keeps essentially the same density as it moves. The parcel can accelerate, turn, or change shape while keeping its volume. Water in an ordinary supply pipe is a good example. Air can often be treated the same way at low speed, provided heating and pressure changes are small.
When can you assume incompressible flow?
Start with the quantity you need to predict. If you use inlet density to convert a measured outlet volume flow to mass flow, a density change directly affects your answer. Compare the expected variation with the accuracy your calculation needs.
- Liquid under pressure
- For a small pressure change at nearly constant temperature, estimate Δρ/ρ ≈ Δp/K, where K is bulk modulus. For water with K ≈ 2.2 GPa, a pressure rise of 1 MPa increases density by about 0.045%. Use fluid properties at the operating temperature.
- Gas accelerating with little heating
- Check the highest local Mach number, M = V/a, where a is the local speed of sound. Mach 0.3 is a useful first screen. For ideal air with γ = 1.4 brought to rest isentropically from M = 0.3, stagnation density is about 4.6% above local static density. A 1% accuracy target calls for a closer check even below Mach 0.3.
- Gas heated or exposed to a large pressure change
- Compare densities at the relevant stations. For the same ideal gas, ρ₂/ρ₁ = (p₂/p₁)(T₁/T₂), using absolute pressures and kelvin temperatures. A slow stream can expand substantially. For large changes along a line, start with the compressible flow guide.
Can slow-moving air be treated as incompressible?
A duct takes in 100 L/s of dry air at 20 °C. Its cross-section is 0.10 m², so the inlet speed is just 1 m/s. Change the outlet temperature while keeping absolute pressure the same. How much air volume must leave each second to carry the same mass?
Outlet density is 12.01% lower. This exceeds the selected 5% limit. Use the outlet density for the volume-flow calculation.
See the calculation for 60 °C
Convert the temperatures to 293.15 K and 333.15 K. At equal pressure, ρ₂/ρ₁ = 293.15/333.15 = 0.8799. From mass conservation, Q₂ = Q₁ρ₁/ρ₂ = 100 × 333.15/293.15 = 113.6 L/s. The density falls by 12.01% relative to the inlet while volume flow rises by 13.64%. The two percentages differ because the ratios are reciprocals.
The comparison assumes steady flow of ideal air of fixed composition, with one inlet, one outlet, and no leakage. The selected limit applies to density variation. Pressure, force, and heat-transfer calculations can have different sensitivities to that variation.
Which incompressible flow equation do you need?
Follow a fluid parcel
Dρ/Dt = 0 and ∇ · u = 0
Dρ/Dt is the rate of density change following the moving parcel. Mass conservation gives Dρ/Dt + ρ∇ · u = 0, so incompressible motion has zero velocity divergence. Fluid may enter one face of a small region faster than before if an equal extra volume leaves through its other faces. Individual velocity components can still change.
Balance flow across a pipe or duct
ṁ = ρQ · Q = A V̄
Q is volume flow (m³/s), ṁ is mass flow (kg/s), and V̄ is the area-averaged velocity normal to the section (m/s). For steady flow with one inlet, one outlet, and no leaks, ρ₁A₁V̄₁ = ρ₂A₂V̄₂ when density is uniform across each section. Equal densities give the familiar continuity equation A₁V̄₁ = A₂V̄₂. At a junction, add the flows in each branch.
Relate pressure, speed, and elevation
p + ½ρV² + ρgz = constant
Ideal Bernoulli applies along a streamline in steady, constant-density flow with negligible viscous losses and no intervening pump or turbine. Here V is local speed, z is elevation, and g is gravitational acceleration. Density can stay constant while pressure falls through a long pipe. Use the pipe flow guide for friction losses or the pump and turbine guide for shaft work when either effect matters.
How fast does water leave a pipe branch?
A full water line carries 6 L/s into a tee. The upper branch takes 2 L/s. The lower branch has a 40 mm inside diameter. Assume steady operation, negligible density change, and no leakage.
- Subtract the known outlet. Qlower = 6 − 2 = 4 L/s = 0.004 m³/s.
- Calculate the open area. A = πD²/4 = π(0.040 m)²/4 = 0.001257 m².
- Find mean speed. V̄ = Q/A ≈ 3.18 m/s. With ρ ≈ 1,000 kg/m³, the inlet carries 6 kg/s and the outlets carry 2 and 4 kg/s.
If both branch flows were unknown, continuity alone would leave two unknowns and one equation. Use the branch pressure losses and downstream conditions to determine the split.
Where does the assumption work, and where does it break down?
- Water distribution
- For ordinary steady service, constant density usually works well for balancing flows. A rapid valve closure poses a different question. Predicting water-hammer wave speed requires both liquid compressibility and pipe-wall flexibility.
- Low-speed airflow around a body
- Check the fastest part of the flow, which can move faster than the approach stream. In external aerodynamics, the local Mach number helps decide whether pressure-driven density variations warrant a compressible model.
- Heated or buoyant flow
- Even a small density difference can drive natural convection. Under the Boussinesq approximation, density is treated as constant in most terms while its small variation is retained in the buoyancy term. For a heater or heat exchanger, connect the flow model to the heat-transfer calculation.
Common questions about incompressible flow
Does incompressible mean steady or laminar?
No. Steady describes conditions at a fixed point over time. Incompressible describes density following a moving parcel. A pump can speed up a water stream while density stays nearly constant, and that stream can be turbulent. Compare laminar and turbulent flow using Reynolds number.
Must density be the same everywhere?
Each parcel must retain its own density in exactly incompressible motion. Parcels can start with different densities, as in idealized layers of fresh and salty water without mixing. Many introductory pipe problems make the additional assumption that density is uniform throughout.
How can I check the assumption with measurements?
For air, measure static absolute pressure and temperature at the inlet and outlet and use the ideal-gas density ratio. Check intermediate extremes if the gas heats and then cools. If using meters, distinguish actual volume flow from a reading referenced to standard conditions. The fluid flow measurement guide covers instrument choices.
Engineering references
- MIT OpenCourseWare — Fluid Mechanics (PDF), for conservation of mass, divergence, and volume change.
- NASA Glenn — Isentropic Flow Equations, for static and stagnation density as functions of Mach number.
- NASA Glenn — Equation of State, for the absolute pressure, temperature, and density relation used in the duct example.
- OpenStax — Stress, Strain, and Elastic Modulus, for bulk modulus and pressure-induced volume change.