Skip to the hose clamp size chart

Hose Clamp Size Chart

SAE #4–#104 adjustment ranges in inches and mm, with a diameter finder and separate Breeze Power-Seal and Mini tables.

Hose clamp sizes: quick SAE chart

All 32 catalog entries

Measure the outside of the hose after it is seated on its fitting. Choose an adjustment range that includes that diameter. Hose inside diameter, nominal pipe size and SAE clamp number are not interchangeable measurements.

Common Breeze Power-Seal clamp ranges; inches are catalog values and mm are calculated.
SAE sizeRange (in)Range (mm)
#67/16–25/3211.11–19.84
#81/2–29/3212.70–23.02
#109/16–1 1/1614.29–26.99
#1211/16–1 1/417.46–31.75
#1613/16–1 1/220.64–38.10
#2013/16–1 3/420.64–44.45
#241 1/16–226.99–50.80
#321 9/16–2 1/239.69–63.50
#402 1/16–352.39–76.20

Quick rows are Breeze Power-Seal (½-in band), not universal SAE adjustment limits. The full chart also includes Breeze Mini #4–#32 (5/16-in band). Sizes and ranges may differ by brand or series.

On this page — jump to a section

Find the right clamp range for your hose

Enter the assembled outside diameter or circumference. The finder lists every matching catalog entry and prioritizes smaller maximum diameters to reduce potential excess band tail. This is a dimensional shortlist, not approval of the joint.

Example: at a measured 32.00 mm assembled OD, Power-Seal #16 (20.64–38.10 mm), #20 (20.64–44.45 mm) and #24 (26.99–50.80 mm) match. Power-Seal #12 ends at 31.75 mm and does not fit a true 32.00 mm OD.

SAE hose clamp size chart — Power-Seal & Mini

32 manufacturer catalog ranges: Power-Seal SAE #6–#104 and Mini SAE #4–#32. Inch dimensions are from the manufacturer. Metric values are precise inch-to-mm conversions rounded to 0.01 mm; actual selections must follow the exact product family.

32 reference rows

Swipe this table horizontally on small screens. Column headings sort when CORE is enabled.

Manufacturer-listed Breeze adjustment ranges; sizes can overlap and differ by product family.
SAE #4 · Mini Mini 7/32 5/8 5.56 15.88 5/16 in
SAE #6 · Power-Seal Power-Seal 7/16 25/32 11.11 19.84 1/2 in
SAE #6 · Mini Mini 7/16 25/32 11.11 19.84 5/16 in
SAE #8 · Power-Seal Power-Seal 1/2 29/32 12.70 23.02 1/2 in
SAE #8 · Mini Mini 1/2 29/32 12.70 23.02 5/16 in
SAE #10 · Power-Seal Power-Seal 9/16 1 1/16 14.29 26.99 1/2 in
SAE #10 · Mini Mini 9/16 1 1/16 14.29 26.99 5/16 in
SAE #12 · Power-Seal Power-Seal 11/16 1 1/4 17.46 31.75 1/2 in
SAE #12 · Mini Mini 11/16 1 1/4 17.46 31.75 5/16 in
SAE #16 · Power-Seal Power-Seal 13/16 1 1/2 20.64 38.10 1/2 in
SAE #16 · Mini Mini 15/16 1 1/2 23.81 38.10 5/16 in
SAE #20 · Power-Seal Power-Seal 13/16 1 3/4 20.64 44.45 1/2 in
SAE #20 · Mini Mini 1 3/16 1 3/4 30.16 44.45 5/16 in
SAE #24 · Power-Seal Power-Seal 1 1/16 2 26.99 50.80 1/2 in
SAE #24 · Mini Mini 1 7/16 2 36.51 50.80 5/16 in
SAE #28 · Power-Seal Power-Seal 1 5/16 2 1/4 33.34 57.15 1/2 in
SAE #28 · Mini Mini 1 11/16 2 1/4 42.86 57.15 5/16 in
SAE #32 · Power-Seal Power-Seal 1 9/16 2 1/2 39.69 63.50 1/2 in
SAE #32 · Mini Mini 1 15/16 2 1/2 49.21 63.50 5/16 in
SAE #36 · Power-Seal Power-Seal 1 13/16 2 3/4 46.04 69.85 1/2 in
SAE #40 · Power-Seal Power-Seal 2 1/16 3 52.39 76.20 1/2 in
SAE #44 · Power-Seal Power-Seal 2 5/16 3 1/4 58.74 82.55 1/2 in
SAE #48 · Power-Seal Power-Seal 2 9/16 3 1/2 65.09 88.90 1/2 in
SAE #52 · Power-Seal Power-Seal 2 13/16 3 3/4 71.44 95.25 1/2 in
SAE #56 · Power-Seal Power-Seal 3 1/16 4 77.79 101.60 1/2 in
SAE #60 · Power-Seal Power-Seal 3 5/16 4 1/4 84.14 107.95 1/2 in
SAE #64 · Power-Seal Power-Seal 3 9/16 4 1/2 90.49 114.30 1/2 in
SAE #72 · Power-Seal Power-Seal 1 7/8 5 47.63 127.00 1/2 in
SAE #80 · Power-Seal Power-Seal 2 1/2 5 1/2 63.50 139.70 1/2 in
SAE #88 · Power-Seal Power-Seal 3 1/8 6 79.38 152.40 1/2 in
SAE #96 · Power-Seal Power-Seal 3 5/8 6 1/2 92.08 165.10 1/2 in
SAE #104 · Power-Seal Power-Seal 4 1/8 7 104.78 177.80 1/2 in

Range is an adjustment diameter, not hose ID. It is normal for multiple clamp numbers to fit one OD. The catalog Power-Seal #72 has an unusually wide 1⅞–5 in range; that entry is intentional. The finder uses unrounded metric boundaries, not rounded 0.01-mm display values.

How to measure for a hose clamp

Fit the hose fully onto the intended barb or tube before measuring. The fitting may stretch the hose, so the diameter of loose hose can give the wrong answer. Measure where the clamp will sit, following the equipment maker’s position requirements.

  1. Use a caliper across the outside. Check more than one direction and location if the hose is not perfectly round. Murray recommends measurements at three locations and their average.
  2. Without a caliper, measure circumference. Wrap a nonstretch strip around the assembled hose, mark the overlap, then measure the strip. For an approximately circular section, diameter equals circumference divided by π.
  3. Record the actual value and units. A 1-in hose ID, a 1-in assembled OD and a 1-in pipe designation are three different specifications.
  4. Check the clamp’s physical fit. Its band, housing and screw need room on the fitting and clearance for installation.

For example, a 100 mm circumference gives an estimated OD of 100 ÷ π = 31.83 mm. This is a geometric estimate; an oval or compressible hose needs a direct fit check. Murray’s sizing guidance.

Measure the outside of the assembled hoseA simplified cross section shows a fitting inside a hose. The overall outside diameter includes the hose walls, while the smaller internal opening is the bore. A hose clamp wraps around the outside.Assembled ODOuter hose surfaceFitting wallOpen boreClamp range refers to outside diameter.Schematic — not to scale.
Measure across the outer hose surface after seating the hose on the fitting. The nominal hose ID is a different dimension.

What SAE clamp numbers do—and do not—tell you

The SAE size is a size designation used in the product catalog. It is not the hose’s inside diameter, the screw’s hex size or the band’s width. Some sizes have overlapping adjustment ranges, so more than one catalog row can contain the same outside diameter.

Do not calculate the adjustment range by multiplying the SAE number by a fixed fraction. Read both limits in the named series. A large maximum diameter does not guarantee that a clamp will close down far enough for a smaller hose.

Two product families with the same SAE number can also have different minimum diameters. The Breeze catalog lists Mini #16 at 15/16–1½ in and Power-Seal #16 at 13/16–1½ in. Their upper limits match, but their lower limits and band widths differ.

Same SAE number, different product family
ExampleBreeze MiniBreeze Power-Seal
SAE #16 range15/16–1½ in13/16–1½ in
Band width5/16 in1/2 in
Size basisVerify exact Mini partVerify exact Power-Seal part

The full reference table on this page now includes both Breeze Mini #4–#32 and Power-Seal #6–#104 as separately labeled rows. Keep the complete manufacturer part number when replacing a clamp. Matching only the stamped number can lose information about screw material, corrosion resistance, band design and installation requirements.

Choose the clamp style as well as the size

Clamp styles and the next specification to check
StyleTypical reason to consider itCheck before substituting
Worm-driveAdjustable range and convenient screw accessHose compatibility, band edges and installation torque
Lined / smooth-bandProtecting softer hose from band perforationsApproved hose and liner design
Spring / constant-tensionHose diameter changes during thermal cyclingWorking diameter and manufacturer selection method
T-boltAn assembly specifies a wider or heavier bandExact working range, bridge fit and bolt torque
Ear / pinchA compact permanent or specified production jointClosure range, correct installation tool and replacement policy
Fuel-injection clampThe fuel-system design requires that clamp typeOEM fuel-system approval and hose specification

The reference chart covers specific worm-drive products. A T-bolt, ear clamp or constant-tension clamp needs its own selection table. A diameter match alone does not make these styles interchangeable. The Power-Seal manufacturer page identifies its band and screw options; the Breeze product catalog separates the other clamp families.

For fuel systems, hydraulic lines, hot coolant and other demanding connections, use the hose assembly and equipment manufacturer’s approved fastening method. Do not treat this general-purpose chart as a pressure rating or as permission to replace a crimped coupling with a worm-drive clamp.

Worked example: selecting a range for a 1.20-in hose OD

Suppose a hose is already installed on its fitting and measures 1.20 in outside. Convert only if helpful: 1.20 × 25.4 = 30.48 mm.

  1. Power-Seal #10 ends at 1 1/16 in, or 1.0625 in, so it is outside this reference range.
  2. Power-Seal #12 covers 11/16–1¼ in, or 0.6875–1.25 in. The measured diameter is within that range.
  3. Power-Seal sizes #16, #20 and #24 also contain 1.20 in, but they offer different adjustment positions and may leave more band tail.
  4. Check the specified material, housing clearance and approved torque for the actual part; then confirm that the assembled joint is suitable for service.

This process produces a shortlist, not a universal “best clamp.” If the application or equipment documentation specifies a particular part, use that requirement instead of choosing by size alone.

Installation checks that prevent a correct size from becoming a poor joint

Confirm the hose is correctly seated, the fitting and hose are undamaged, and the band sits where the equipment instructions require it. A band partly over the edge of a barb or a damaged hose cannot be corrected simply by tightening the screw harder.

Use the installation torque for the exact clamp family, screw material and hose assembly. Do not substitute a destructive-test torque or a maximum catalog torque for an installation setting. Torque units also matter: in·lb and ft·lb differ by a factor of 12.

When ordering, specify manufacturer, family, size or working range, band width, band/housing/screw materials, and the intended service. A stainless band does not necessarily mean every component is the same stainless grade; NORMA lists several Power-Seal screw/material combinations.

A clamp does not have one pressure capacity independent of the joint. Hose construction, fitting geometry, assembly quality and the type of pressure loading all affect performance. Murray explains why its clamp selection depends on the complete assembly. Follow the equipment’s verification procedure before returning a connection to service.

Hose Clamp Size Chart FAQ

What size clamp do I need for a 1/2-inch hose?

Measure the assembled outside diameter first. “1/2-inch hose” commonly describes the bore, so wall thickness and the installed fitting still affect the required clamp range. Enter the actual OD in the finder.

What is the size range of a #12 hose clamp?

For the Breeze Power-Seal reference used here, #12 covers 11/16–1¼ in, equivalent to 17.46–31.75 mm after rounding. Confirm the range for the brand and family you are buying.

How big is a #20 hose clamp?

Breeze Power-Seal #20 has an adjustment range of 13/16–1¾ in, or approximately 20.64–44.45 mm. It is not a 20 mm-only clamp.

Are hose clamp sizes based on inside or outside diameter?

The adjustment range refers to the outside diameter around which the clamp closes. Measure the outside of the hose with the fitting installed, not the flow passage or nominal pipe size.

Why do two hose clamp charts show different sizes?

They may cover different product families, use different adjustment limits, or round inch dimensions differently in millimeters. Keep the manufacturer, series and unit basis with the range.

Can I use a much larger hose clamp if it tightens far enough?

Only if its specified working range and the full assembly requirements are satisfied. Excess band tail, poor housing fit or an unsuitable band can still make it a poor choice. Prefer the specified part or verify the substitution with the manufacturer.

Can I reuse a hose clamp?

Follow the equipment and clamp maker’s replacement instructions. Damage, corrosion, stretched parts and one-time closure designs may require replacement. Size alone cannot establish whether a used clamp remains serviceable.

What is the difference between SAE #16 Mini and Power-Seal clamps?

For the Breeze ranges used here, Mini #16 is 15/16–1½ in (23.81–38.10 mm), whereas Power-Seal #16 is 13/16–1½ in (20.64–38.10 mm). The band widths are also different: 5/16 in for Mini and 1/2 in for Power-Seal. Match the complete series, not just the SAE number.

What size hose clamp fits a 32 mm outside diameter?

At 32 mm measured assembled OD, Breeze Power-Seal #16, #20 and #24 all include the diameter, and additional wide-range sizes may also match. Size #12 ends at 31.75 mm and is not a match for a true 32.00 mm OD. Use the finder to see the family-specific matches and check the actual joint.

Can I convert circumference into hose clamp size?

Yes. Measure a snug circumference around the assembled hose, then divide by π to estimate the outside diameter. The finder accepts inches or millimeters and converts automatically. For oval or compressible hose, check directly with a caliper.

Why is SAE #72 smaller at its minimum than SAE #64?

Breeze Power-Seal #72 has an unusually wide published range of 1⅞–5 in, while #64 spans 3 9/16–4½ in. The number alone is not a safe formula for the minimum diameter; always consult the actual series table.

Sources, rounding and chart limitations

All 32 size rows are sourced to the named Breeze product families. The 22 Power-Seal ranges (SAE #6–#104) and 10 Mini ranges (SAE #4–#32) use the manufacturer’s inch-defined adjustment limits. Millimeter conversions are derived using exactly 25.4 mm per inch and rounded half-up to 0.01 mm for display. Finder comparisons use unrounded values. A label shared by two families does not mean identical closed diameters, band widths, materials, or approvals.

Manufacturer and guidance source check: October 29, 2026. Always confirm the current catalogue and application-specific fitting requirements.

Scroll to Top