HDPE Pipe Size Chart

Look up IPS, DIPS, and CTS HDPE pipe outside diameter, minimum wall thickness, approximate average inside diameter, DR/SDR, and PE4710 pressure class.

Material
PE4710 HDPE
Systems
IPS · DIPS · CTS
Default
IPS · DR 11 · inches

Interactive reference

HDPE Pipe Size & Dimension Chart

Source-controlled OD and minimum wall values with calculated approximate average ID.

Start with the sizing system and DR used by the project. Nominal size is a designation—not the actual OD or ID.

Scroll horizontally to view additional columns and vertically to view additional rows. The nominal size column and column headers remain visible while scrolling.

PE4710 HDPE pressure-pipe dimensions derived from PPI/MAB-6 Appendix F. Default no-JavaScript view is IPS DR 11. Pressure classes use the PPI/MAB-3 2026 water-service basis up to 80°F.
Actions
4 in IPS DR 11 4.500 in ±0.020 in 0.409 in 3.633 in 200 psi
6 in IPS DR 11 6.625 in ±0.030 in 0.602 in 5.348 in 200 psi
8 in IPS DR 11 8.625 in ±0.039 in 0.784 in 6.963 in 200 psi
10 in IPS DR 11 10.750 in ±0.048 in 0.977 in 8.678 in 200 psi
12 in IPS DR 11 12.750 in ±0.057 in 1.159 in 10.293 in 200 psi
14 in IPS DR 11 14.000 in ±0.063 in 1.273 in 11.302 in 200 psi
16 in IPS DR 11 16.000 in ±0.072 in 1.455 in 12.916 in 200 psi
18 in IPS DR 11 18.000 in ±0.081 in 1.636 in 14.531 in 200 psi
20 in IPS DR 11 20.000 in ±0.090 in 1.818 in 16.145 in 200 psi
22 in IPS DR 11 22.000 in ±0.099 in 2.000 in 17.760 in 200 psi
24 in IPS DR 11 24.000 in ±0.108 in 2.182 in 19.375 in 200 psi
26 in IPS DR 11 26.000 in ±0.117 in 2.364 in 20.989 in 200 psi
28 in IPS DR 11 28.000 in ±0.126 in 2.545 in 22.604 in 200 psi
30 in IPS DR 11 30.000 in ±0.135 in 2.727 in 24.218 in 200 psi
32 in IPS DR 11 32.000 in ±0.144 in 2.909 in 25.833 in 200 psi
34 in IPS DR 11 34.000 in ±0.153 in 3.091 in 27.447 in 200 psi
36 in IPS DR 11 36.000 in ±0.162 in 3.273 in 29.062 in 200 psi
42 in IPS DR 11 42.000 in ±0.189 in 3.818 in 33.905 in 200 psi

Average ID is an engineering approximation, not a guaranteed bore. For MAB-6 F-1/F-2/F-3 OD-controlled rows, it follows PPI Handbook Chapter 6 Eq. 2-1: average ID = OD − 2.12(OD ÷ DR). For F-4/F-5 rows with an explicit wall tolerance, the estimate uses minimum wall plus half the listed tolerance. Manufacturer dimensions and project requirements govern procurement.

Dimension guide

HDPE Pipe OD, ID & Wall Thickness

The diagram explains what the chart dimensions mean and updates when a row is viewed.

HDPE pipe cross-section showing outside diameter, inside diameter, and wall thickness Generic cross-section. The outer circle represents outside diameter, the inner circle represents approximate average inside diameter, and the radial gap represents wall thickness. Diagram is not to scale. OD Approx. average ID t
Conceptual cross-section; wall is exaggerated for readability and the drawing is not to scale.
Selected pipe
Generic HDPE pipe
Average OD
Outer diameter
Minimum wall, t
Wall thickness
Approx. average ID
Inner diameter

Interpret the numbers

What HDPE Pipe Size Actually Means

An HDPE nominal size is a designation used to identify a pipe series; it is not automatically the outside diameter or the inside diameter. The sizing system must be known before you choose fittings, compare materials, or enter a diameter into a hydraulic calculation.

IPS
Iron Pipe Size. For the large sizes in MAB-6 Table F-1, an 8 in IPS pipe has an average OD of 8.625 in.
DIPS / DIOD
Ductile Iron Pipe Size outside-diameter series. The same 8 in nominal size has a 9.050 in average OD.
CTS
Copper Tube Size. MAB-6 Table F-4 provides CTS SDR 9 rows from ¾ through 2 in nominal size.

Compatibility warning: Do not treat IPS and DIPS as interchangeable because their actual ODs differ. Verify the pipe print line, fittings, valves, restraints, and project specification.

HDPE DR and SDR

Dimension ratio relates pipe outside diameter to minimum wall thickness. For the same OD, a lower DR means a thicker wall. The chart keeps the source-listed minimum wall instead of recalculating it from rounded display values.

For the PE4710 AWWA water-service basis in MAB-3 Table 1, the preferred pressure classes shown are valid up to 80°F. They are not universal ratings for every polyethylene compound, temperature, fluid, installation, or surge condition.

Dimension ratioDR = outside diameter ÷ minimum wall thickness

Use source dimensions and project requirements; do not infer manufacturer availability from geometry alone.

DR 17
125 psi PE4710 pressure class
DR 13.5
160 psi PE4710 pressure class
DR 11
200 psi PE4710 pressure class
DR 9
250 psi PE4710 pressure class

How approximate average ID is calculated

The chart does not call OD − 2 × minimum wall an average bore. For OD-controlled DR rows in MAB-6 F-1 through F-3, it uses the PPI Handbook Chapter 6 average-ID relationship average ID = OD − 2.12(OD ÷ DR). For the small F-4/F-5 SDR 9 rows that list an explicit wall tolerance, it uses minimum wall plus half that tolerance as average wall. The result remains an approximation; actual ID varies with manufacturing tolerances.

Source checkpoints

Worked HDPE Size Examples

Example 1: 8 in IPS, DR 11

Source dimensions: average OD = 8.625 in; minimum wall = 0.784 in.

PPI Handbook Eq. 2-1 gives approximate average ID = 8.625 − 2.12(8.625 ÷ 11) ≈ 6.963 in.

Interpretation: use the 6.963 in approximation—not the 8 in nominal designation—when a preliminary calculation specifically requires an estimated internal diameter. Confirm the manufacturer’s dimensions for final design.

Example 2: 8 in DIPS, DR 11

Source dimensions: average OD = 9.050 in; minimum wall = 0.823 in.

PPI Handbook Eq. 2-1 gives approximate average ID = 9.050 − 2.12(9.050 ÷ 11) ≈ 7.306 in.

Sanity check: the DIPS pipe has a larger OD and a larger approximate ID than the same nominal 8 in IPS DR 11 pipe. That is why nominal size alone cannot establish fitting compatibility or bore.

Avoid common mistakes

HDPE Pipe Selection & Sizing Checks

Confirm the OD series first

Read the project specification and pipe marking before using a chart. An 8 in IPS row and an 8 in DIPS row are physically different outside diameters.

Do not reverse DR logic

For a fixed OD, DR 11 is thicker-wall than DR 17. The smaller dimension-ratio number corresponds to the larger wall thickness.

Treat ID as approximate

Inside diameter is affected by OD and wall tolerances. Use manufacturer-specific dimensions when equipment fit, metering, pigging, or tight hydraulic tolerances matter.

Check pressure conditions

The pressure-class values on this page are the PE4710 AWWA basis cited by MAB-3 up to 80°F. Temperature, surge, installation, fluid, and project criteria can change the governing design.

Do not mix U.S. and metric designation systems

PE100/PN and ISO metric pipe tables use different designation conventions. They should be handled as a separate reference rather than merged into this U.S. PE4710 chart.

Verify thick-wall availability

MAB-6 instructs users to consult the manufacturer where listed wall thickness exceeds 3 in. A source-listed geometric row does not guarantee commercial availability.

Standards, Sources & Scope

PE4710 solid-wall pressure-pipe reference for U.S. IPS, DIPS/DIOD, and CTS sizing; not an ISO PE100/PN table.

The page reorganizes a limited engineering reference into a searchable format and adds calculated approximate average ID. It does not reproduce the source document’s original table arrangement and does not offer a bulk source-data download.

Dataset and Source-Check Details

Publisher
Turn2Engineering
Source checked
August 15, 2026
Canonical dimensions
Inches; metric display is converted at 25.4 mm/in
Calculated field
Approximate average ID
Missing values
Unavailable source combinations are omitted rather than extrapolated
Rights / download
Copyrighted PPI/MAB references; no bulk source-data CSV

Design use: This chart is an engineering reference, not project approval. Verify the current project standard and manufacturer dimensions before procurement, joining, pressure design, or final hydraulic calculations.

HDPE Pipe Size Chart FAQs

The pressure-pipe systems shown here are outside-diameter controlled series; nominal size is a designation and should not be assumed to equal the actual OD or ID.

Use the Actual HDPE Dimension, Not the Nominal Label

For a reliable lookup, confirm the sizing system first, then the nominal size and DR. Use the chart’s source-listed OD and minimum wall values, treat the displayed average ID as an approximation, and verify manufacturer/project requirements before final design or procurement.