Which circuit breaker works with your panel?
Full chart ↓Which breaker fits your panel? Start with the breaker types printed on the exact panel label. Other brands require a specific classified replacement document; matching size or amperage alone is not proof of compatibility.
Quick answer: Square D QO and Homeline branch breakers are not interchangeable, and Eaton CH and BR are different systems. A Type CL classified breaker may be permitted in specifically identified panels, never by brand alone. Use the complete chart and original references below if the interactive lookup is unavailable.
Choose your panel to see its original breaker family. Optionally choose a candidate breaker to see what documentation must be checked; no selection here certifies an installation.
Breaker compatibility chart by panel brand
Identify the original panel-listed breaker family first, then evaluate any specifically classified alternative by exact catalog number. “Conditional” is not blanket approval. Consult the source linked in each row and the labeling on your actual panel.
Common examples: Square D QO → QO branch family; Square D Homeline → HOM branch family; Eaton CH → CH; Eaton BR → BR; Siemens/ITE QP panels → approved QP-type variants. Always match the specific panel label.
No matching rows. Clear the search or reset the page.
On a narrow screen, swipe the table horizontally to see every column. The first column stays visible.
| Manufacturer / source document | ||||
|---|---|---|---|---|
| Square D QO | QO branch family; match exact panel label | Eaton QO-classified family only for documented combinations; current brochure uses CHFQ, older material CHQ | HOM is not interchangeable with QO; QOB bolt-on is a different mounting format | Schneider catalog |
| Square D Homeline | HOM branch family; match exact panel label | Eaton Type CL only where the exact breaker and panel are on its classification list | QO is not interchangeable with HOM; ordinary Eaton BR is not Type CL | Schneider catalog |
| Eaton / Cutler-Hammer CH | CH branch family and required functional variants | No general cross-brand alternate established by this chart | CH and BR are different families; similar branding is insufficient | Eaton CH documentation |
| Eaton / Cutler-Hammer BR | BR branch family and required functional variants | No general cross-brand alternate established by this chart | BR, CH and CL have different designations; preserve the panel listing | Eaton BR documentation |
| Siemens / ITE QP-type | QP family or listed rating/functional variant on label | Eaton Type CL for exact combinations listed in its classification document | QP, QPH and HQP ratings differ; not every Siemens breaker fits every Siemens panel | Siemens QP instructions |
| Murray — specified post-Jan 2002 lines | Matched Siemens replacement under its substitution letter | Eaton Type CL for exact combinations listed in its classification document | Siemens letter covers Meter Combo, EQ Small Circuit and Rock Solid lines manufactured after Jan 2002 | Siemens replacement letter (archive) |
| Murray — pre-Jan 2002 / date unknown | Use the types on the particular panel wiring diagram | Eaton Type CL only if that exact panel and breaker are listed | Do not apply the post-Jan 2002 Siemens statement to all older Murray panels | Siemens replacement letter (archive) |
| GE / ABB Q-Line load centers | THQL and other types expressly identified by panel documentation | Eaton Type CL for exact listed panel/breaker combinations | Half-width THQP requires the correct panel provisions and positions | ABB load-center guide |
| Bryant / Westinghouse / Challenger BR-line | Current Eaton equivalent for the exact legacy type | Use Eaton legacy cross-reference and panel labeling | Legacy brand name alone does not identify every product line | Eaton legacy cross-reference |
| Crouse-Hinds MP-type legacy | Panel-label types; identify the exact legacy model | Eaton Type CL for exact listed MP-type panel/breaker combinations | Acquisition history or a 1 in shape is not an approval | Eaton classified compatibility list |
| Thomas & Betts TB-type legacy | Panel-label types; identify the exact legacy model | Eaton Type CL for exact listed TB-type panel/breaker combinations | Do not substitute ordinary BR solely because it physically seats | Eaton classified compatibility list |
| Leviton load centers | Leviton branch breakers specified for the load center | No general cross-brand alternate established by this chart | Smart capability, neutral connection and part generation must match instructions | Leviton breaker catalog |
| Other / unidentified legacy panel | Identify manufacturer, catalog number and permitted breaker types | Only documented listed or classified replacements for the exact equipment | This chart establishes no substitution for unidentified, damaged or unsupported equipment | UL panelboard marking guide |
Primary classification principle: UL Solutions marking and application guide. Eaton Type CL compatibility is controlled by its exact panelboard/meter-center list. Product scope and suffixes can change; use the current instructions supplied with the breaker. No automatic interchange is implied by any row.
Circuit Breaker Compatibility Chart — all 13 reference rows. Read the stated conditions and sources.
On this page
Listed, specified and UL Classified: what each means
A panel manufacturer identifies breaker types investigated for use in its equipment. That panel labeling is the normal first reference. A breaker also carries its own certification and ratings. Its general product certification does not mean it is suitable for every panel that accepts its physical shape.
A classified replacement is a documented alternative investigated for particular equipment. UL’s application guide explains that the compatibility list identifies the classified breaker, its ratings, the applicable panelboards and the original breakers it can replace. The list also sets supply-system limits.
An original-equipment manufacturer may specify only its own breakers. A separately classified replacement is a distinct, limited certification route that must name the exact equipment and comply with its instructions. Physical fit or matching ampere rating is never a sufficient interchange rule.
Important manufacturer distinction: Schneider Electric instructs owners of its QO and Homeline load centers to use the specified Square D breakers and warns about other manufacturers’ devices. Separately, UL describes a limited pathway for appropriately Classified replacements in specified panelboards. These are not universal permissions; verify the actual classification, equipment instructions, applicable code and authority having jurisdiction (AHJ).
How to verify a replacement in five steps
- Identify the panel. Record its manufacturer, catalog number and permitted branch-breaker types from accessible documentation. Identify the actual product line, not just the name on a door that may have been replaced.
- Identify the existing circuit’s requirements. Record the poles, amperage, voltage, conductor requirements and whether AFCI, GFCI or dual-function protection is required.
- Find the permitted replacement route. Match the panel label, the manufacturer’s replacement documentation or the classified breaker’s exact panel list. Keep the relevant document with the circuit records.
- Check all restrictions. Review interrupting rating, available fault current, series-rating implications, neutral connection, allowable positions and any fastening or accessory requirements.
- Confirm the installation condition. A compatible replacement does not correct damaged bus contacts, overheating or a deteriorated panel. A qualified electrician should assess the equipment and installation requirements.
Do not remove a cover or work inside an energized panel to collect these details. Turning off the main does not necessarily de-energize incoming service conductors.
Before purchase: “Compatible” here means a route to documentation—not approval to install. A qualified person should evaluate the exact breaker catalog number, the panel model and condition, required circuit protection, interrupting rating, series rating, and applicable electrical code.
Eaton CL, CHQ and CHFQ: read the exact scope
Eaton’s Type CL range provides classified replacements for specified combinations involving Homeline, GE, Siemens/ITE, Murray, Crouse-Hinds and Thomas & Betts equipment. The actual compatibility list contains exact panel and breaker entries; a manufacturer’s name appearing in the brochure is not enough.
The retrieved Type CL compatibility sheet specifies a single-phase, three-wire 120/240 V supply and a maximum available short-circuit current of 10 kA. Confirm those values against the actual document for the breaker and application, including any restrictions on poles and protective functions. Do not carry a panel’s unrelated series rating over to a replacement without documentation. UL describes the applicable classified-breaker panelboard scope as rated 225 A or less.
Eaton’s July 2026 brochure names CHFQ for its QO replacement examples; older catalog material names CHQ. This page preserves that distinction and directs you to the supplied classification instructions. Ordinary CH and BR breakers are not automatically the classified versions of those products.
Murray and other legacy panels
Siemens 2019 substitution letter (archived copy) covers Murray Meter Combo, EQ Small Circuit and Rock Solid load centers manufactured after January 2002. It includes mappings such as Murray MP-T / MP-HT / MP-MT to Siemens QP / QPH / HQP. The corresponding rating and type still matter.
For pre-January 2002 Murray equipment, the letter directs the reader to the breaker types on the panel’s wiring diagram. Treat an unknown date as unresolved. A second-hand statement that “Siemens bought Murray” is not a substitute for the equipment-specific evidence.
For Bryant, Westinghouse and Challenger equipment in the BR lineage, Eaton provides a replacement cross-reference. Identify the exact legacy type before using it. The same legacy brand may have been used on different equipment; a family table cannot certify every panel that ever carried that name.
Why the same amperage and width are not enough
Interrupting rating describes the fault current the device can interrupt under its rating conditions. Ampere rating describes the circuit’s normal current rating. A 20 A rating says nothing by itself about whether a breaker can interrupt the available fault current at that panel.
Poles and trip: a pair of one-pole devices does not automatically provide the required behavior of a common-trip two-pole breaker. Follow the required circuit arrangement and approved accessories. Protection: preserve required AFCI, GFCI and dual-function features. “Combination-type AFCI” is not the same label as a dual-function AFCI/GFCI device.
Mounting and neutral: plug-in, bolt-on, pigtail-neutral and plug-on-neutral designs have different requirements. Tandem positions, rejection features and permitted circuit counts also require the panel’s instructions. The front handle and opening width are only a small part of the interface.
Three examples that avoid common selection errors
QO panel, HOM breaker: Schneider explicitly says the branch families are not interchangeable. Their shared Square D brand does not change that.
Homeline panel, Eaton CL candidate: this is a possible classified route. Find the exact Homeline panel catalog number and the exact CL part and rating in the current classification document. If either is absent, the broad family chart has not established approval. An Eaton BR that looks similar is not the same evidence.
GE panel, half-width replacement: use the GE/ABB product and panel documentation to confirm the half-width design and its permitted positions. Do not infer that because a full-width THQL is allowed, any half-width device is also allowed.
These examples apply the same principle: preserve the electrical function and the equipment’s documented combination. A purchase that saves a few minutes at the counter can create a much larger problem if a required rating or function is lost.
Circuit Breaker Compatibility Chart FAQs
Can I mix circuit breaker brands in one panel?
Only when the exact combination is supported by the panel labeling or an applicable classified-breaker listing and all conditions are met. The presence of mixed brands in an existing panel does not prove that the combinations were correctly selected.
Are Square D QO and Homeline breakers interchangeable?
No. Schneider states that the QO and Homeline branch families must be used with their corresponding load centers. See the manufacturer answer.
Are Eaton BR and CH breakers interchangeable?
No. They are separate breaker and load-center families. The Eaton or Cutler-Hammer brand name does not replace the CH or BR type designation and the exact panel labeling.
Will a Siemens breaker work in a Murray panel?
Siemens permits matched replacements in the specific post-January 2002 Murray lines covered by its Siemens 2019 substitution letter (archived copy). For earlier or unidentified equipment, verify the types on that panel wiring diagram and the exact replacement documentation.
Is an Eaton CL breaker the same as an Eaton BR?
No. CL identifies the classified replacement range addressed by its compatibility documents. BR belongs to the BR system and applicable legacy replacement routes. Similar appearance does not transfer the listing of one designation to the other.
Does UL Listed mean a breaker works in any panel?
No. General certification and panel-specific suitability are separate checks. The relevant panel instructions or classified compatibility document must cover the proposed combination, including its ratings and restrictions.
Can I replace an AFCI breaker with a standard breaker if it fits?
Physical fit does not preserve required protection. Determine the circuit requirements and use the correctly listed or classified device with the needed AFCI, GFCI or dual-function capability. A standard overcurrent breaker does not provide those additional functions.
What breakers are compatible with Square D Homeline panels?
Start with the Homeline (HOM) branch-breaker types on the particular panel label. Square D QO is not a Homeline substitute. Eaton Type CL offers a separate, limited classified route for specified panel-and-breaker combinations; a standard Eaton BR is not that classification. Confirm the exact part, poles, protective function and restrictions.
Are Siemens and GE breakers interchangeable?
No general interchangeability is established by brand or physical size. Siemens QP and GE/ABB THQL/THQP belong to different breaker systems. Use the exact panel’s permitted types or an applicable classification list that names both pieces of equipment.
Can I install a tandem breaker in any empty panel slot?
No. A tandem/duplex breaker is limited to panel designs and individual positions listed for that configuration. Check the panel label, bus design, rejection features and permissible circuit count. An empty space is not evidence of approval.
What if the breaker panel label is missing or unreadable?
Do not guess from the breaker shape, door branding or an online brand chart. Identify the enclosure and load-center catalog number from accessible records, manufacturer documentation or a qualified electrician. This page cannot certify an unidentified panel.
Sources and Data Basis
Manufacturer and UL documentation checked October 25, 2026. This is a U.S. branch-breaker family guide, not a code approval or substitute for current breaker-supplied instructions.
- UL Solutions — Molded Case Circuit Breaker Marking and Application GuideClassified-breaker compatibility lists, panel identification and supply-system conditions.
- Eaton — Type CL panelboard / meter-center compatibility listExact listed panel and breaker combinations; supply and fault-current limits. Use the document supplied for the actual breaker.
- Eaton — Classified breaker brochure, July 2026Current published CL and CHFQ family examples; brochure is not a substitute for exact compatibility instructions.
- Schneider Electric — QO and Homeline interchangeabilityManufacturer expressly distinguishes QO and HOM branch families.
- Siemens — Murray substitution letter, September 5, 2019 (archived copy)Specified post-January 2002 Murray lines, corresponding Siemens types and earlier-panel limitation.
- Eaton — Legacy replacement referenceExact legacy type cross-references for Cutler-Hammer, Westinghouse, Challenger and Bryant.
- ABB — OEM Load Centers Product Guide1TQC164000E0001, revision C: PowerMark product-specific THQL/THQP space counts and interior drawings. Check the exact equipment label and approved positions.
- Leviton — Residential circuit breakersLeviton breaker family and load-center context.
- Schneider Electric — QO/Homeline load-center guidanceOriginal equipment manufacturer’s position on other-brand branch breakers and its warranty/listing warnings.
- Schneider Electric — QO and Homeline catalogManufacturer breaker family and load-center selection documentation.
- Eaton — CH, BR and Classified load centers/breakersOfficial product family overview distinguishing CH, BR and separately Classified variants.
- Siemens — QP / MP branch breaker installation instructionsOfficial Siemens/Murray breaker-family documentation; panel labeling governs the approved combinations.